@22:56:40.28PDT09-Oct-22
>BREAK< ESP3 Gateway v1.12 for core bus @22:56:40.30 >BREAK< ESP3 Gateway v1.12 for cartridge bus @22:56:42.82 Configuration for mv1 on Koa's dome -- 10/5/22 brent@mbari.org /home/esp/esp2/type/auv/mv1/configure.rb @22:56:43.18 Sea pressure (Abs) tare is 10% of full scale @22:56:47.37 Polling Can every 2:00 @22:56:48.37 Clients may connect on TCP port 9999 @22:56:48.38 Connecting to 10.89.5.2:9999 @22:56:48.43 Errno::ECONNREFUSED in MAIN -- Could not connect to initial client because Connection refused - connect(2) @22:56:48.46 Waiting for espclients... @22:59:25.06 Session Begun @22:59:36.76 -> ESP.configure @22:59:36.80 Gate.power :main,:ON,limit to 5000mA @22:59:36.82 Gate.power :analytic1,:ON,limit to 5000mA @22:59:36.84 Gate.power :analytic2,:ON,limit to 5000mA @22:59:36.87 Gate.power :analytic3,:ON,limit to 5000mA @22:59:36.93 Powering core bus @22:59:39.63 Archive.configure :default @22:59:39.76 Air.configure :default @22:59:39.87 Lysis1.configure :default @22:59:39.97 Lysis2.configure :default @22:59:40.10 Plunge.configure :default @22:59:40.23 SamplePump.configure :default @22:59:40.36 Toroid.configure :default @22:59:40.48 Carousel.configure :default @22:59:40.61 Pressure.configure :default @22:59:40.74 ExtraPump.configure :default @22:59:40.80 All elf controllers running firmware version 4.798 @22:59:40.82 Gate.power :motor,:ON,limit to 5000mA @22:59:45.73 -> Intake.open @22:59:45.74 Intake.open Intake is opened @23:00:03.67 -> time {Intake.close} @23:00:03.69 Intake.close <#:0xfdb4abc34 result=Intake duration=.649108 seconds> @23:00:25.10 -> time {Exhaust.open} @23:00:25.12 Exhaust.open <#:0xfdb4aa38c result=Exhaust duration=.646732 seconds> @23:00:30.95 -> time {Exhaust.close} @23:00:30.96 Exhaust.close <#:0xfdb4a8bf8 result=Exhaust duration=.620064 seconds> @23:03:16.58 -> time {Exhaust.close} <#:0xfdb4a7b0c result=Exhaust duration=.000415 seconds> @23:03:36.98 -> 5.times {Intake.open; Intake.close} @23:03:36.99 Intake.open @23:03:37.64 Intake.close @23:03:38.28 Intake.open @23:03:38.93 Intake.close @23:03:39.60 Intake.open @23:03:40.25 Intake.close @23:03:40.88 Intake.open @23:03:41.54 Intake.close @23:03:42.17 Intake.open @23:03:42.78 Intake.close 5 @23:03:51.49 -> 5.times {Intake.open; Intake.close} @23:03:51.50 Intake.open @23:03:52.17 Intake.close @23:03:52.80 Intake.open @23:03:53.42 Intake.close @23:03:54.04 Intake.open @23:03:54.71 Intake.close @23:03:55.28 Intake.open @23:03:55.86 Intake.close @23:03:56.48 Intake.open @23:03:57.10 Intake.close 5 @23:04:17.14 -> ESP.closeValves [] @23:04:24.66 -> Cmd.stop @23:04:24.81 Slide::Error in brent -- Storage Carousel (SC) Not yet Homed! @23:04:24.83 Retry #1 of 2 @23:04:24.99 Gate.power :motor,:OFF @23:04:25.00 Gate.power :core,:OFF @23:04:25.03 Gate.power :analytic1,:OFF @23:04:25.05 Gate.power :analytic2,:OFF @23:04:25.09 Gate.power :analytic3,:OFF @23:04:25.11 Gate.power :main,:OFF @23:04:27.23 UserAbort in brent -- User Abort!! @23:04:39.17 -> ESP.ready! @23:04:39.21 Gate.power :main,:ON,limit to 5000mA @23:04:39.23 Gate.power :analytic1,:ON,limit to 5000mA @23:04:39.25 Gate.power :analytic2,:ON,limit to 5000mA @23:04:39.28 Gate.power :analytic3,:ON,limit to 5000mA @23:04:39.34 Powering core bus @23:04:42.04 Archive.configure :default @23:04:42.17 Air.configure :default @23:04:42.28 Lysis1.configure :default @23:04:42.39 Lysis2.configure :default @23:04:42.51 Plunge.configure :default @23:04:42.64 SamplePump.configure :default @23:04:42.77 Toroid.configure :default @23:04:42.89 Carousel.configure :default @23:04:43.02 Pressure.configure :default @23:04:43.14 ExtraPump.configure :default @23:04:43.21 All elf controllers running firmware version 4.798 @23:04:43.22 Gate.power :motor,:ON,limit to 5000mA @23:04:43.47 Air.in :default @23:04:44.01 Archive.in :default @23:04:44.16 Air.home.jog 0 @23:04:44.18 Archive.home.jog 0 @23:04:44.37 Plunge.in :default @23:04:44.42 Lysis2.in :default @23:04:44.52 Toroid.in :default @23:04:44.54 Lysis1.in :default @23:04:44.74 Plunge.home.jog 0 @23:04:44.77 Lysis1.home.jog 0 @23:04:44.79 Toroid.home.jog 0 @23:04:44.82 Lysis2.home.jog 0 @23:04:45.21 Archive.in :homing @23:04:45.24 Air.in :homing @23:04:45.33 Archive.jog 1368 @23:04:45.36 Air.jog 1368 @23:04:45.54 Plunge.in :homing @23:04:45.57 Lysis2.in :homing @23:04:45.61 Toroid.in :homing @23:04:45.64 Lysis1.in :homing @23:04:45.78 Plunge.jog 774 @23:04:45.81 Lysis2.jog 1359 @23:04:45.88 Toroid.jog 638 @23:04:45.94 Lysis1.jog 1369 @23:04:46.53 Archive.setRawPosition! 50 @23:04:46.59 Archive.seek :home @23:04:46.67 Air.setRawPosition! 50 @23:04:46.73 Air.seek :home @23:04:46.81 Plunge.setRawPosition! 50 @23:04:46.87 Plunge.seek :home @23:04:46.95 Archive.in :default @23:04:47.05 Air.in :default @23:04:47.12 Lysis2.setRawPosition! 50 @23:04:47.20 Lysis2.seek :home @23:04:47.29 Lysis1.setRawPosition! 50 @23:04:47.31 Plunge.in :default @23:04:47.41 Lysis1.seek :home @23:04:47.51 Lysis2.in :default @23:04:47.70 Lysis1.in :default @23:04:48.13 Toroid.setRawPosition! 0 @23:04:48.18 Toroid.seek :home @23:04:48.28 Toroid.in :default @23:04:48.40 Toroid.seek :clear @23:04:50.01 Carousel.in :default @23:04:50.07 Carousel.home.jog 0 @23:04:50.56 Carousel.in :default @23:04:50.62 Carousel.seek 55 Archive = Archive Syringe (ArS) clear Air = Air Syringe (AirS) clear Lysis1 = Lysis Syringe #1 (LyS1) clear Lysis2 = Lysis Syringe #2 (LyS2) clear Plunge = Plunge Valve (PV) clear Handoff Valve::Manifold selects blocked SamplePump = Sample Pump (SP) Not yet Homed! Intake is closed Exhaust is closed Bypass = Bypass (PB) is closed Toroid = Toroid Valve (TV) clear Carousel = Storage Carousel (SC) at 55 Pressure = Absolute Pressure (Leak) Sensor @16.6psia @23:04:55.85 -> Cmd.stop @23:04:56.00 Carousel.seek 55 @23:04:56.18 Lysis1.in :fast @23:04:56.24 Lysis1.seek :locked @23:04:58.40 Plunge.seek :locked @23:04:59.35 Lysis1.in :unlocking @23:04:59.47 Lysis1.seek :clear @23:05:00.71 Gate.power :motor,:OFF @23:05:00.73 Gate.power :core,:OFF @23:05:00.76 Gate.power :analytic1,:OFF @23:05:00.78 Gate.power :analytic2,:OFF @23:05:00.80 Gate.power :analytic3,:OFF @23:05:00.83 Gate.power :main,:OFF @23:05:00.85 Safely stopped and ready to power off :STOPPED @23:05:07.91 -> Intake.open @23:05:07.93 Intake.open @23:05:07.97 BusOff in brent -- Intake is not powered! @23:05:18.44 -> exit @23:05:18.45 Session Ended